Removing FEP
tubes: → p. 142
The cleaning valve
(3) is just labelled
in this illustration to
identify it for preventive
maintenance and is not
part of the procedure.
170
Repair > Milk Module Repairs (Plastic Component Support)
11.13.9 Replace Steam Heating Chamber
3
A
Prerequisites
• Hydraulic unit and PCB assembly are detached → p. 160.
Procedure
1. Remove the FEP tubes (A+B) on both sides of the steam heating chamber (2).
2. Push the steam heating chamber (2) slightly upwards to release it from the latch
(circled in red, see detail).
3. Pull the steam heating chamber (2) out of its support.
4. Remove the FEP tube (C) from the steam valve (4, see photo).
5. Remove the steam heating chamber (2) together with the FEP tube (C).
Momento 120 Service Manual
4
B
C
1
2
Fig. 140
Version 1.4 EN