Setting The Flap Clamps To The Flap Rest Table - DURKOPP ADLER 745-35-10 F Service Instructions Manual

Hide thumbs Also See for 745-35-10 F:
Table of Contents

Advertisement

Feeding device
2. Turn the piston rod (6).
3. Tighten the counternut (5).
4. If necessary, readjust the shanks (3) and (4).

13.4.4 Setting the flap clamps to the flap rest table

The swivel width of the flap clamps and the position of the flap rest table
can be adjusted separately.
The swivel width of the flap clamps can be adjusted individually to the
requirements of the user.
Fig. 141: Setting the flap clamps to the flap rest table (1)
(1) - Flap clamp
(2) - Flap rest table
(3) - Sliding plate
(4) - Transport clamp
Proper setting
The flap rest table must be set such that the stationary flap clamp (1) is
flush and parallel to the flap rest table (2).
The distance between flap clamp (1) and flap rest table is 8 - 12 mm.
Service Instructions 745-35-10 B/745-35-10 F - 00.0 - 10/2017
(5) - Folding plate
(6) - Middle of the pocket opening
(7) - Pick-up folder
(8) - Flap clamp transport clamp
157