Folder
12.5.3 Setting the pick-up folder position in sewing direction
Fig. 124: Setting the pick-up folder position in sewing direction
(1) - Screws
To set the position of the pick-up folder in sewing direction:
1. Loosen the screws (1).
2. Shift the lowered pick-up folder in sewing direction.
The distance between pick-up folder and folder is 0.5 mm.
3. Tighten the screws (1).
Service Instructions 745-35-10 B/745-35-10 F - 00.0 - 10/2017
NOTICE
Property damage may occur!
Possible damage to folder sole and folding plates.
Make sure that the sole of the pick-up folder rests on the fabric sliding
plate along its entire length.
①
0.5 mm
141