3. Place the gage (3) on the throat plate support (4).
 The measuring sleeve (2) of the gage must reach over the hook shaft
4. Check if the flange surface (1) of the hook shaft abuts on the measuring
FIg. 34: Setting the height of the hook shaft (2)
(5) - Plastic stoppers
(6) - Sleeve
5. Swivel up the machine head ( p. 14).
6. Remove the plastic stoppers (5).
7. Loosen the screws found below the plastic stoppers (5).
8. Loosen the screws (7).
9. Slide the flange surface of the hook shaft (1) under the measuring
10. Tighten the screws found below the plastic stoppers (5).
11. Slide the sleeve (6) against the hook shaft as far as it will go.
12. Tighten the screws (7) on the surfaces of the sleeve (6).
13. Re-assemble hook and throat plate ( p. 54).
44
journal.
sleeve (2) of the gage.
sleeve (2) of the gage.
To do so, position a screwdriver under the flange surface (1). If the
hook shaft position is too high, lightly tap on the flange surface (1) to
push the hook shaft down.
(7) - Screw
Service Instructions 745-35-10 B/745-35-10 F - 00.0 - 10/2017
Machine head