8.2.1 Setting the light barriers for automatic slant detection

Fig. 100: Setting the light barriers for automatic slant detection (1)
(1) - Template for straight pockets
To set the light barriers for automatic slant detection:
1. Insert the sewing material.
2. Open the menu Service > Machine test and press the button
3. Swing the folding station out.
4. Press the
 Reference run is carried out.
5. Press the
 The light barriers must be aligned with the transport clamp position.
6. Press the
 The flap clamp opens.
116
WARNING
Risk of injury from moving parts!
Crushing possible.
Do not reach into the travel path of the transport
clamps.
The folding station must be swung out.
Align light barriers
button.
button and select the desired transport clamp position.
button.