15.5 Pocket bag on flap (745-35-10 B only)

15.5.1 Aligning the flap clamps

The flap clamps are set at the OP7000 control panel ( p. 275).

15.5.2 Setting the guide plates at folder and pick-up folder

Fig. 184: Setting the guide plates at folder and pick-up folder
(1) - Folder guide plate
(2) - Inner guide plate
(3) - Guide plate point
Order
First, check the following settings:
• Position of the folder guide plate ( p. 142)
196
• Guide plate height
• Spring pressure
• Lateral position to the needle
0.3 - 0.5 mm
(4) - Guide plate
(5) - Guide plate at pick-up folder
(6) - Nuts
Service Instructions 745-35-10 B/745-35-10 F - 00.0 - 10/2017