Machine head
Disassembling the needle bar linkage
FIg. 17: Disassembling the needle bar linkage (1)
(4) - Screw
(5) - Screws
(6) - Thread advancing device
To remove the needle bar linkage:
1. Loosen screws (4) and (7).
2. Remove the thread advancing device (6).
3. Unscrew the screws (5).
4. Unscrew the screw (8).
Service Instructions 745-35-10 B/745-35-10 F - 00.0 - 10/2017
④
⑧
⑤
(7) - Screw
(8) - Screw
⑦
⑥
27