Setting The Initial Position Of The Flap Turning Device - DURKOPP ADLER 745-35-10 F Service Instructions Manual

Hide thumbs Also See for 745-35-10 F:
Table of Contents

Advertisement

Feeding device
4. Set the lateral play.
5. Tighten the clamping nut (2).

13.5.3 Setting the initial position of the flap turning device

Fig. 147: Setting the initial position of the flap turning device (1)
90 mm
Important
Proper operation of the flap turning device is only ensured if the gear is set
as shown above.
The initial position of the flap turning device must be set after every
change of the toothed belt.
Setting the initial position
Fig. 148: Setting the initial position of the flap turning device (2)
(1) - Cylinder
(2) - Threaded pins
To set the initial position:
1. Loosen the threaded pins (2).
2. Turn the cylinder (1) clockwise until reaching a value of 63°.
162
Service Instructions 745-35-10 B/745-35-10 F - 00.0 - 10/2017