Chapter 8: Making Software Performance Measurements
Duration Performance Measurements
From Address
800F7
File main(module)."/users/guest/demo/debug_env/hp64767/main.c"
Symbolic Reference at interrupt_sim+A6
To Address
80051
File main(module)."/users/guest/demo/debug_env/hp64767/main.c"
Symbolic Reference at _interrupt_sim
Number of intervals
Maximum Time 132505.760 us
Minimum Time 99983.480 us
Avg Time
109555.798 us
Statistical summary - for
Stdv 14821.94
95% Confidence 0.74% Error tolerance
Graph of relative percents
1 us 10 us
10.1 us 100 us
100.1 us 500 us
500.1 us 1 ms
1.001 ms 5 ms
5.001 ms 10 ms
10.1 ms
20 ms
20.1 ms
40 ms
40.1 ms
80 ms
80.1 ms
160 ms
160.1 ms 320 ms
320.1 ms 640 ms
640.1 ms 1.2 s
Two sets of information are given in the duration measurement report: module
duration and module usage.
The first set of information in the duration measurement report is the "module
duration" measurement. The module duration report shows that the amount of time
it takes for the interrupt_sim function to execute varies from 39.8 microseconds to
592 milliseconds. The average amount of time it takes for the interrupt_sim module
to execute is roughly 63.6 milliseconds.
The second set of information in the duration measurement report is the "module
usage" measurement. Module usage measurements show how much time is spent
outside the module of interest; they indicate how often the module is used. The
information shown in the first part of the duration report above shows that the
average amount of time spent outside the interrupt_sim function is about 109.6
milliseconds.