Nortel 8300 Troubleshooting Manual page 129

Ethernet routing switch
Hide thumbs Also See for 8300:
Table of Contents

Advertisement

Step
1
2
Variable definitions
Variable
duration <integer>
interval <integer>
Job aid: Configuration example
This configuration example uses the preceding commands to set the sample
interval to 10 seconds and the sample duration to 500 seconds. These
settings cause the switch to take a sample every 10 seconds, continue
sampling for a duration of 500 seconds, and then return to the system
prompt.
Passport-8310:5(config)#monitor-stats
Passport-8310:5(config)#monitor-stats interval 10
Configuring the duration/interval of the monitor commands
using the CLI
Use the following procedure to set the monitor duration and interval.
Procedure steps
Copyright © 2007, Nortel Networks
.
Action
To configure the duration of the monitor command, enter the
following command:
monitor-stats duration <integer>
To configure the interval of the monitor command, enter the
following command:
monitor-stats interval <integer>
Nortel Ethernet Routing Switch 8300
Troubleshooting
NN46200-704 01.01 Standard
4.0 29 October 2007
—End—
Value
Sets the length of the monitor period.
To clear the display, type Ctrl/L.
<integer> is an integer value with a
range of 1 to 1800 seconds. The
default is 300 seconds
Sets the frequency of the update
interval. To clear the display, type
Ctrl/L.
<integer> is an integer value with a
range of 1 to 600 seconds. The default
is 5 seconds.
Monitoring ports 129

Advertisement

Table of Contents
loading

Table of Contents