Gathering Phone/IP Details

E1 Telephony Parameters (for TA3010)

The following parameters must be known about the PBX or telco central office equipment to which the E1
TalkAnytime unit will connect:
E1 Phone Parameters
Ask phone company or
PBX maintainer.
• Which frame format is used?
• Which CAS or PRI protocol is used? ______________
• Clocking: Does the PBX or telco switch use
internal
Note that the setting used in the TalkAnytime unit will
be the opposite of the setting used by the telco/PBX.
• Which line coding is used?
• Pulse shape level?: (most commonly 0 to 40 meters)
Write down the values for these E1 parameters. You will need to enter these values in the "T1/E1/ISDN
Parameters" screen in the Configuration section of the TalkAnytime software.
Info needed to operate:
E1 Parameters:
Record for this
TalkAnytime unit.
Double Frame
MultiFrame w/ CRC4
MultiFrame w/ CRC4 modified
or
clocking? _________________
external
___ or
AMI
TalkAnytime Quick Start Instructions
TA3010
_____
_____
_____
___
HDB3