E1 Statistics: Field Definitions (cont'd)
Field
Values
Name
Receive
Timeslot 16
Loss of
MultiFrame
Alignment
Transmit
Line Open
Transmit
Data
Underrun
Transmit
Slip
Negative
Bipolar
Integer tally of
Violation
violation count
since last reset.
Excessive
Tally since last
Zeroes
reset.
Transmit
Tally since last
Slip
reset.
Receive Slip
Tally since last
reset.
Description
The framing pattern '0000' in 2
consecutive CAS multiframes were not
found or in all time slot 16 of the previous
multiframe all bits were reset.
At least 32 consecutive zeroes were
transmitted.
For use by MTS Technical Support
Personnel.
The frequency of the transmit clock is
greater than the frequency of the transmit
system interface working clock. A frame
is skipped.
Bipolar Violation (or BPV) refers to two
successive pulses of the same polarity on
the E1 line. On an AMI-encoded line, this
represents a line error. On a B8ZS line,
this may represent the substitution for a
string of 8 zeroes.
Displayed value will increment if
consecutive zeroes beyond a set threshold
are detected. I.e., tally increments if more
than 7 consecutive zeroes in the received
data stream are detected under B8ZS line
coding, or if 15 consecutive zeroes are
detected under AMI line coding.
Slip in transmitted data stream. Slips
indicate a clocking mismatch (or lack of
synchronization) between T1/E1 devices.
When slips occur, data may be lost or
repeated.
Slip in received data stream. Slips indicate a
clocking mismatch (or lack of synchronization)
between T1/E1 devices. When slips occur, data
may be lost or repeated.