Electrical system
Sensor box error (inertia sensor platform) P0712
•
Faulty sensor/Signal not valid
Troubleshooting:
With faulty sensor, the component inside the control unit is damaged and replacement of the control
unit is recommended. With signal not valid, the sensor has generated a signal out of range that is still
sent to the injection control unit together with the relevant error.
Sensor box error (inertia sensor platform) P0713
•
Faulty sensor/Signal not valid
Troubleshooting:
With faulty sensor, the component inside the control unit is damaged and replacement of the control
unit is recommended. With signal not valid, the sensor has generated a signal out of range that is still
sent to the injection control unit together with the relevant error.
Connectors
ECU
ELE SYS - 236
RSV4 Factory a-PRC