Battery recharge circuit
RECHARGE SYSTEM (Mitsubishi - Kokusan)
Remove the left side fairing;
Disconnect the three-way connector
(1) (white).
NOTE
THE ENGINE SIDE IS IDENTIFIED WITH THE LETTER "A"
Measurement of resistance (with engine off)
For a correct detection of the alternator
resistance, an ambient temperature
measurement must be carried out and
afterwards a heat stabilisation (after
turning fan on) by using a tester, using
alternatively the 3 connector pins:
stage "1" (pin 1-2), stage "2" (pin 1-3),
stage "3" (pin 2-3).
Take the measurement; The correct value is determined by the value measured for each
stage in which from time to time the resistance of the tester wires is subtracted, obtained by
touching the two lugs.
Example:
Resistance of stage 1 read on the display = 0.62 Ohm
Electrical system