If shorted to positive: excessive voltage has been detected at PIN 58; if the circuit is open,
shorted to negative: voltage equal to zero has been detected.
DIAGNOSTICS INSTRUMENT: LOGIC ERRORS
Starter switch P0169
signal not valid.
Error cause
Fault in the switch (lock) of the engine start-up. The instrument panel does not indicate the
presence of this error even in the ATT status.
Troubleshooting
Check the locking cause and restore.
level indicators
See also
Fuel pump
Fuses
Specification
A) 5A fuse
B) 5A fuse
C) 15A fuse
D) 7.5A fuse
E) 15A fuse
F) 15A fuse
G) 15A fuse
CAUTION
THREE OF THE FUSES ARE SPARES (H).
Specification
L) 30A fuse
AUXILIARY FUSES DISTRIBUTION
Lights relay, stop light, daylight running lights, variable geom-
Instrument panel, turn indicators, speed, instrument panel di-
Coils, injectors, fuel pump, oxygen sensor and secondary air
MAIN FUSES DISTRIBUTION
Battery recharge and vehicle current consumers, injection cur-
Desc./Quantity
etry intake ducts (factory)
agnosis, tone wheel ECU (a-PRC)
Control unit
Control unit
High beam/low beam, horn.
valve
Fans.
Desc./Quantity
rent consumers (red and red/white cables).
Electrical system