Download Print this page

APRILIA RSV4 Factory a-PRC 2009 Service Station Manual page 177

Advertisement

RSV4 Factory a-PRC
NOTE: pressure estimated by the control unit according to the throttle position
Rear Cylinder estimated Intake Pressure (1 and 3)
Example value with key ON: 1004 mbar
Example value with engine on: 735 mbar
NOTE: pressure estimated by the control unit according to the throttle position
CAUTION
BEFORE CARRYING OUT ANY TROUBLESHOOTING, CAREFULLY READ THE GENERAL TROU-
BLESHOOTING CONCEPTS FOR ELECTRICAL DEVICES AT THE BEGINNING OF THE CHECK
AND CONTROL SECTION IN THE ELECTRICAL SYSTEM CHAPTER.
DIAGNOSIS INSTRUMENT: ELECTRICAL ERRORS
rear cylinder air pressure sensor P0105
shorted to positive / open circuit, shorted to negative.
Error cause
If shorted to positive: excessive voltage has been detected at PIN 24. If the circuit is open,
shorted to negative: voltage equal to zero has been detected at PIN 24.
Troubleshooting
If shorted to positive: see that the parameter of the rear cylinders air Pressure Sensor on
the diagnosis instrument reads approx. 1200 mbar; disconnect the sensor connector: if the
value does not vary, it means that the cable is shorted between the control unit connector
and the sensor connector: restore the cable harness; Replace the sensor if the value varies.
If the circuit is open, shorted to negative: check the Marelli control unit connector and the
sensor connector; if not OK, restore. If everything is OK, with key set to OFF, check if there
is continuity between the PIN 24 of the Marelli control unit and the sensor connector PIN 3:
if there is no continuity, restore the cable harness. If there is continuity, check the cable
ground insulation: if there is continuity to ground, restore the cable harness; if not, with key
set to ON check that the voltage on sensor connector PIN 1 is approx. 5 V: if not OK, set
the key to OFF and check continuity between the ENGINE connector PIN 25 and the sensor
connector PIN 1: if not OK, restore the cable harness; if OK, replace the control unit; if there
is 5V voltage at PIN 1, and with key set to ON, check the continuity to ground of the sensor
connector PIN 3: if not OK, restore the cable harness; if OK, replace the sensor.
front cylinder air pressure sensor P0106
shorted to positive / open circuit, shorted to negative.
Error cause
If shorted to positive: excessive voltage has been detected at PIN 49. If the circuit is open,
shorted to negative: voltage equal to zero has been detected at PIN 49.
Troubleshooting
Electrical system
ELE SYS - 177

Advertisement

loading

This manual is also suitable for:

Rsv4 factory a-prc 2010Rsv4 factory a-prc 2011