Electrical system
CAUTION
BEFORE CARRYING OUT THIS OPERATION, CHECK THAT THE BATTERY VOLTAGE IS HIGHER
THAN 12.5 V
CAUTION
OPERATE ON THE CONTROL MOTOR OF THE EXHAUST VALVE ONLY WITH THE KEY "OFF"
OR ONLY AFTER DISCONNECTING THE NEGATIVE POLE OF THE BATTERY.
CAUTION
NEVER REMOVE THE PULLEY FROM THE CONTROL MOTOR
CAUTION
LOOSEN THE ADJUSTER SCREWS OF THE CONTROL CABLES BEFORE REMOVAL, TO AVOID
HAVING TO FORCE THEM.
CAUTION
BEFORE REMOVING THE CONTROL CABLES, CHECK THAT THE MOTOR PULLEY IS IN THE
"ZERO" POSITION. NEVER OPERATE ON THE CONTROL CABLES IF THE MOTOR PULLEY IS
NOT IN THE "ZERO" POSITION
EXHAUST THROTTLE VALVE CALIBRATION
•
From the Adjustable parameters
screen page, use the diagnostic instru-
ment to select: Acquire exhaust valve
zero position
•
After having pressed the enter button
for the zero position search, shut off the
vehicle and leave the keys in OFF,
even in the event that the instruments
indicate the opposite.
•
Slacken the exhaust throttle valve ca-
ble tension.
NOTE
IF IT IS NECESSARY TO REPLACE THE MOTOR, FROM
POSITION ZERO LOOSEN THE CABLES COMPLETELY TO
REMOVE THEM, THEN, AFTER DISCONNECTING THE
CONNECTOR, REMOVE THE MOTOR ITSELF.
ELE SYS - 228