Electrical system
Value drawn from the signal read without taking
into account any recovery: the value in the exam-
ple refers to an open circuit
CAUTION
BEFORE CARRYING OUT ANY TROUBLESHOOTING,
CAREFULLY READ THE GENERAL TROUBLESHOOTING
CONCEPTS FOR ELECTRICAL DEVICES AT THE BEGIN-
NING OF THE CHECK AND CONTROL SECTION IN THE
ELECTRICAL SYSTEM CHAPTER.
DIAGNOSIS INSTRUMENT: ELECTRICAL ERRORS
air temperature sensor P0110
open circuit, shorted to positive / shorted to negative
Error cause
If the circuit is open, shorted to positive: excessive voltage has been detected at PIN 37 of
the ENGINE connector. If shorted to negative: voltage equal to zero has been detected. The
instrument panel does not indicate the presence of this error even in the ATT status.
Troubleshooting
If the circuit is open, shorted to positive: check the sensor connector and the Marelli control
unit connector. If they are OK, check sensor continuity: replace the sensor if not OK; if OK,
check continuity between the ENGINE connector PIN 37 and the sensor PIN 1: restore cable
harness if there is not continuity; if it is OK, reconnect the control unit connector and, with
key set to key ON, check the continuity between the sensor connector PIN 2 and the vehicle
ground connection: if OK, it means that the error cause is that the cable is shorted to positive
and it is necessary to restore the cable harness between ENGINE PIN 37 and sensor PIN
1; check the sensor connector and the Marelli control unit connector. If not OK, restore the
cable harness. If OK, check continuity between the ENGINE connector PIN 6 or 17 and the
sensor connector PIN 2: restore the cable harness if there is not continuity. If there is, it
means that the control unit does not supply the ground connection and therefore should be
replaced
If shorted to negative, check sensor correct resistance: if resistance = 0, replace the sensor;
if resistance is correct, it means that the grey cable has ground connection: restore the cable
harness