RSV4 Factory a-PRC
activation. The continuity of the wiring is necessary for correct activation: no error indications
are displayed in case of lack of activation
DIAGNOSIS INSTRUMENT: ELECTRICAL ERRORS
Upper injector cylinder 1 P0205
short circuit to positive/ short circuit to negative / open circuit
Error cause
If shorted to positive: excessive voltage has been detected at PIN 53. If shorted to negative:
no voltage has been detected. If the circuit is open: an interruption has been detected
Troubleshooting
If shorted to positive: disconnect the injector connector, set key to ON, activate the compo-
nent with the diagnosis instrument and check the voltage on the orange/red cable on the
injector connector (if there is voltage): if there is voltage, restore the filter box cable harness.
If there is no voltage, replace the sensor
If shorted to negative: disconnect the injector connector, set the key to ON and check if there
is a ground connection on the orange/red cable: if there connection, restore the cable har-
ness. If there is no connection, replace the injector.
If the circuit is open: check the component correct electrical characteristic: if it is not the
correct one, replace the component; if it is correct, check the connector on the component
and the Marelli control unit connector: if not OK, restore. If OK, check cable continuity be-
tween PIN 53 and component PIN - and restore the cable harness
Upper injector cylinder 2 P0206
short circuit to positive/ short circuit to negative / open circuit
Error cause
If shorted to positive: excessive voltage has been detected at PIN 67. If shorted to negative:
no voltage has been detected. If the circuit is open: an interruption has been detected
Troubleshooting
If shorted to positive: disconnect the injector connector, set key to ON, activate the compo-
nent with the diagnosis instrument and check the voltage on the white/green cable on the
injector connector: if there is voltage, restore the filter box cable harness. If there is no
voltage, replace the sensor
If shorted to negative: disconnect the injector connector, set the key to ON and check if there
is a ground connection on the white/green cable: if there connection, restore the cable har-
ness. If there is no connection, replace the injector.
If the circuit is open: check the component correct electrical characteristic: if it is not the
correct one, replace the component; if it is correct, check the connector on the component
Electrical system
ELE SYS - 195