ICP-CC488 | Quick Reference Guide | 1.0
1.13
Telephone Monitor Mode (Toggle
On/Off)
1. Enter the four character Installer Code, followed
by [6] and the [#] key (for example, [1 2 3 4 6
#]).
2. Press and hold the [9] key until two beeps are
heard to send a test report.
Table 6:

Telephone Monitor Mode

Zone LED
Dialing Event
1
Telephone Line Seized
2
Dialing Telephone Number
3
Handshake Received
4
Data Being Sent
5
Kiss-Off Received
None
Released Telephone Line
You must exit from Telephone Monitor
Mode to resume normal operations.
1.14
Add/Delete User Code/RF Keyfob
1.14.1
Add A User Code
1. Enter the four character Master Code, followed
by [1] and the [#] key (for example, [2 5 8 0 1
#]).
2. Enter the User Number (1 to 16) you want to
add/change, followed by the [#] key.
3. Enter the new code, followed by the [#] key.
1.14.2
Add RF Keyfob
1. Enter the four character Master Code, followed
by [1] and the [#] key (for example, [2 5 8 0 1
#]).
2. Enter the User Number (9 to 16) you want to
add, followed by the [#] key.
3. Enter the 9-digit RF keyfob ID number, followed
by the [#] key.
1.14.3
Delete a User Code/RF Keyfob
1. Enter the four character Master Code, followed
by [1] and the [#] key (for example, [2 5 8 0 1
#]).
2. Enter the User Number (1 to 16) you want to
delete, followed by the [#] key.
3. Press the [*] key to delete the User Code.
Bosch Security Systems, Inc. | 12/08 | F01U089458-02
Overview
1.15
Change Domestic Telephone
Numbers
1. Enter the four character Installer Code or Master
Code, followed by [2] and the [#] key (for
example, [1 2 3 4 2 #]).
2. Enter the digits for the telephone number.
3. If there is more than one telephone number,
press the [*] key, followed by the [4] key (inserts
break between phone numbers) and repeat Step
2, or press the [#] key to exit.
1.16
Turn Outputs On/Off
1. Enter the four character Master Code, followed
by [5] and the [#] key (for example, [2 5 8 0 5
#]).
2. Enter the Output Number (1 to 3) you want to
toggle on or off.
3. Press the [#] key to toggle on or the [*] key to
toggle off.
4. Press the [#] key to exit.
1.17
Setting Date and Time
1. Enter the four character Master Code, followed
by [6] and the [#] key (for example, [2 5 8 0 6
#]).
2. Enter the day (DD), month (MM), and year (YY)
followed by the hour (HH) and minute (MM).
3. Press the [#] key to exit.
1.18
Day Alarm – Toggle On/Off
Press and hold the [4] key until two beeps are heard.
Day alarm toggles on or off.
1.19
STAY Mode 2 Zones – Program
1. Enter the four character Installer Code or Master
Code, followed by [4] and the [#] key (for
example, [1 2 3 4 4 #]).
2. Enter the Zone Number you want the system to
automatically isolate, followed by the [*] key.
Repeat if more than one zone must be
automatically isolated when armed in STAY
Mode 2.
3. Press the [#] key to exit.