SyriXus Series Pumps Installation and Operation Guide
Section 7 Modbus Configuration
Register Address Type Size
00065
64
R/W
00066
65
R/W
00067
66
R/W
00068
67
R/W
00069
68
R/W
00070
69
R/W
00071
70
R/W
00072
71
R/W
00073
72
R/W
00074
73
R/W
00075
74
R/W
00076
75
R/W
00077
76
R/W
00078
77
R/W
00079
78
R/W
00080
79
R/W
00081
80
R/W
00082
81
R/W
00083
82
R/W
00084
83
R/W
00085
84
R/W
00086
85
R/W
00087
86
R/W
00088
87
R/W
00089
88
R/W
00090
89
R/W
00091
90
R/W
00092
91
R/W
00093
92
R/W
00094
93
R/W
00095
94
R/W
00096
95
R/W
EAR99 Technology Subject to Restrictions Contained on the Cover Page
7-6
Table 7-6 Coils (Continued)
1 BIT 0: AUTO REFILL C OFF
1 BIT 0: AUTO REFILL D OFF
1 BIT 0: AUTO FILL A OFF
1 BIT 0: AUTO FILL B OFF
1 BIT 0: AUTO FILL C OFF
1 BIT 0: AUTO FILL D OFF
1 BIT 0: DIGITAL OUTPUT BIT 1 HIGH
1 BIT 0: DIGITAL OUTPUT BIT 2 HIGH
1 BIT 0: DIGITAL OUTPUT BIT 3 HIGH
1 BIT 0: DIGITAL OUTPUT BIT 4 HIGH
1 BIT 0: DIGITAL OUTPUT BIT 5 HIGH
1 BIT 0: DIGITAL OUTPUT BIT 6 HIGH
1 BIT 0: DIGITAL OUTPUT BIT 7 HIGH
1 BIT 0: DIGITAL OUTPUT BIT 8 HIGH
1 BIT 0: Disable Dispense Mode A
Only configure if in Constant Flow Mode
1 BIT 0: Disable Dispense Mode B
Only configure if in Constant Flow Mode
1 BIT 0: Disable Dispense Mode C
Only configure if in Constant Flow Mode
1 BIT 0: Disable Dispense Mode D
Only configure if in Constant Flow Mode
1 BIT 1: Reset total volume delivered by multi-pump pair AB
1 BIT 1: Reset total volume delivered by multi-pump pair CD
1 BIT 1: Pressure Units = ATM
1 BIT 1: Pressure Units = BAR
1 BIT 1: Pressure Units = kPa
1 BIT 1: Pressure Units = PSI
1 BIT 1: Flow Units = mL/min
1 BIT 1: Flow Units = mL/hr
1 BIT 1: Flow Units = µL/min
1 BIT 1: Flow Units = µL/hr
1 BIT 0: Overpressure Alarm OFF
1 BIT 0: Overpressure Display OFF
1 BIT 0: Overpressure Shutdown OFF
1 BIT 0: Underpressure Alarm OFF
Description
1: AUTO REFILL C ON
1: AUTO REFILL D ON
1: AUTO FILL A ON
1: AUTO FILL B ON
1: AUTO FILL C ON
1: AUTO FILL D ON
1: DIGITAL OUTPUT BIT 1 LOW
1: DIGITAL OUTPUT BIT 2 LOW
1: DIGITAL OUTPUT BIT 3 LOW
1: DIGITAL OUTPUT BIT 4 LOW
1: DIGITAL OUTPUT BIT 5 LOW
1: DIGITAL OUTPUT BIT 6 LOW
1: DIGITAL OUTPUT BIT 7 LOW
1: DIGITAL OUTPUT BIT 8 LOW
1: Enable Dispense Mode A
1: Enable Dispense Mode B
1: Enable Dispense Mode C
1: Enable Dispense Mode D
1: Overpressure Alarm ON
1: Overpressure Display ON
1: Overpressure Shutdown ON
1: Underpressure Alarm ON