Teledyne SyriXus 65x Installation And Operation Manual page 133

Syringe pumps
Table of Contents

Advertisement

Register Address Type Size
00032
31
R/W
00033
32
R/W
00034
33
R/W
00035
34
R/W
00036
35
R
00037
36
R
00038
37
R
00039
38
R
00040
39
R
00041
40
R
00042
41
R
00043
42
R
00044
43
R
00045
44
R
00046
45
R
00047
46
R/W
00048
47
R/W
00049
48
R/W
00050
49
R/W
00051
50
R/W
00052
51
R/W
00053
52
R/W
00054
53
R/W
00055
54
R/W
00056
55
R/W
00057
56
R/W
00058
57
R/W
00059
58
R/W
00060
59
R/W
00061
60
R/W
00062
61
R/W
00063
62
R/W
00064
63
R/W
EAR99 Technology Subject to Restrictions Contained on the Cover Page
SyriXus Series Pumps Installation and Operation Guide
Table 7-6 Coils (Continued)
1 BIT 1: Activates the automatic rapid pressurization cycle (Constant Flow Mode only)
for Pump A
1 BIT 1: Activates the automatic rapid pressurization cycle (Constant Flow Mode only)
for Pump B
1 BIT 1: Activates the automatic rapid pressurization cycle (Constant Flow Mode only)
for Pump C
1 BIT 1: Activates the automatic rapid pressurization cycle (Constant Flow Mode only)
for Pump D
1 BIT 1: Pump A is Equilibrating
1 BIT 1: Pump B is Equilibrating
1 BIT 1: Pump C is Equilibrating
1 BIT 1: Pump D is Equilibrating
1 BIT 1: Pump A is in Hold (clock stopped)
1 BIT 1: Pump B is in Hold (clock stopped)
1 BIT 1: Pump C is in Hold (clock stopped)
1 BIT 1: Pump D is in Hold (clock stopped)
1 BIT 1: Pump A & Pump B in Concentration Gradient
1 BIT 1: Pump A in Pressure Gradient
1 BIT 1: Pump A in Flow Gradient
1 BIT 1: Controller in Local Operation
1 BIT 1: Controller in Remote Operation
1 BIT 1: Controller in External Operation
1 BIT 1: External Refill control enabled
1 BIT 1: Zero pressure sensor offset for Pump A
1 BIT 1: Zero pressure sensor offset for Pump B
1 BIT 1: Zero pressure sensor offset for Pump C
1 BIT 1: Zero pressure sensor offset for Pump D
1 BIT 0: Pressure Integrator for Pump A OFF
1 BIT 0: Pressure Integrator for Pump B OFF
1 BIT 0: Pressure Integrator for Pump C OFF
1 BIT 0: Pressure Integrator for Pump D OFF
1 BIT 0: Pressure Deadband for Pump A OFF
1 BIT 0: Pressure Deadband for Pump B OFF
1 BIT 0: Pressure Deadband for Pump C OFF
1 BIT 0: Pressure Deadband for Pump D OFF
1 BIT 0: AUTO REFILL A OFF
1 BIT 0: AUTO REFILL B OFF
Section 7 Modbus Configuration
Description
1: Pressure Integrator for Pump A ON
1: Pressure Integrator for Pump B ON
1: Pressure Integrator for Pump C ON
1: Pressure Integrator for Pump D ON
1: Pressure Deadband for Pump A ON
1: Pressure Deadband for Pump B ON
1: Pressure Deadband for Pump C ON
1: Pressure Deadband for Pump D ON
1: AUTO REFILL A ON
1: AUTO REFILL B ON
7-5