Section 8 Serial Interface
8.8 Serial
Commands for
the SyriXus
Series Pumps
Command (Refer to
NOTE 1 & NOTE 2
%B=#
ALOG1
ALOG2
ALOG3
ALOG4
ALOG5
ALOG6
CLEAR
CONTIN CONST FLOW
CONTIN CONST FLOWCD
CONTIN CONST PRESS
CONTIN CONST PRESSCD
CONTIN MODIFIER
CONST FLOW
CONST FLOWB
CONST FLOWC
CONST FLOWD
CONST PRESS
CONST PRESSB
CONST PRESSC
CONST PRESSD
DELIVER
DELIVERCD
DIGITAL
EAR99 Technology Subject to Restrictions Contained on the Cover Page
8-20
It is important to follow this format. Spaces are ignored anywhere
within the message field. Commands must be in uppercase letters.
The network definition allows multiple commands in a message field
when delimited by semicolons, but the SyriXus series controller is
l i m i t e d t o s i n g l e c o m m a n d s . I t w i l l r e s p o n d w i t h a
PROBLEM=INVALID COMMAND message.
Table 8-3 "Serial Commands" is a list of the serial commands recog-
nized by the pump. These commands are the message part of the
DASNET protocol. The operand always follows the equals sign. The
REMOTE command must be sent once, before any command that
changes the operation of the pump will be accepted.
When setting a value, the serial command will always be followed by
an equal sign.
Table 8-3 Serial Commands
.)
Enter # for percentage of modifier.
Status of the analog voltage input on pin 21, P6.
Status of the analog voltage input on analog input 3 of the accessory connector.
Status of the analog voltage input on analog input 2 of the accessory connector.
Status of the analog voltage on analog input 1 of the accessory connector.
Status of the analog voltage input for Press 'D'.
Status of the analog voltage on analog input 4 of the accessory connector.
Stops all motors, sets flow rate and pressure setpoints to zero.
Puts pump in continuous flow under Constant Flow Mode.
Puts pump in continuous flow under Constant Pressure Mode.
Put pump in continuous Modifier Addition Mode.
Put pump in Constant Flow Mode.
Put pump in Constant Pressure Mode.
Set the dual-pump mode to deliver fluid when running.
Returns the status (High or Low) of the digital outputs. Format is digital = xxxxxxxx,
where 'x' is either 'H' or 'L'. The status order returned corresponds with the outputs
1—8. "X"= no change.