Programming a Waveform Quality/Code Domain Measurement

This section provides an example of how to make a waveform quality measurement via GPIB.
The following program example assumes that the mobile station's antenna output is connected to the RF
IN/OUT connector, and the mobile station has found service.
The basic procedure to measure waveform quality is as follows:
1. Make a call.
2. Configure the waveform quality measurement setup parameters using the
3. Start the waveform quality measurement using the
4. Use the
"FETCh:WQUality"
5. Use the
"FETCh:WQUality:CDPower:ICHannel[:ALL]?"
"FETCh:WQUality:CDPower:QCHannel[:ALL]?"
results.

Programming Example

10
RE-SAVE "c:\roadhog\programs\wqu.txt"
20
!This program measures waveform quality
30
!Refer to "Waveform Quality and Frequency Accuracy" in EIA/TIA-IS-98D for standards and
specifications
40
CLEAR SCREEN
50
A=714
60
!***Specify call parameters***
70
Systype$="DIGITAL2000" !Cell System Type
80
Band$="USCELLULAR" !Cell band
90
Channel=384 !RF Channel
100
Sid=1 !System Identification
110
Nid=1 !Network Identification
120
Radio_config$="F3R3" !Radio Configuration
130
Service_opt$="SO2"
140
!
150
!***Specify test parameters***
160
Loss_frequency$="851 MHZ,896 MHZ" !Reverse channel, forward channel frequencies for
amplitude offset (path loss)
170
Expected_loss$="-2,-2" !Path loss at reverse channel, forward channel frequencies
180
Ior=-50!Cell power
190
Pilot=-7 !Pilot channel power level
200
Traffic=-7.4 !Traffic channel power level
210
!
220
ON TIMEOUT 7,20 CALL Timeout ! Calls "Timeout" routine
230
OUTPUT A;"SETUP:WQU:TIMEOUT:STIME 10 S" !Sets waveform quality measurement timeout to 10
seconds
240
OUTPUT A;"SYST:COMM:GPIB:DEB:STAT ON"!Turns debug state on
250
!
260
!***Set up call parameters***
270
OUTPUT A;"CALL:OPER:MODE CALL" !Sets Operating Mode to Active Cell
command to obtain waveform quality measurement results.
commands to obtain code domain power measurement
!Loopback service option
S:\Hp8960\E1962B CDMA 2000\Pi Release\Reference Guide\Chapters\cdma2000_prog_wquality.fm
Programming a Waveform Quality/Code Domain Measurement
"INITiate"
subsystem.
or
"SETup:WQUality"
subsystem.
188