Agilent Technologies 8960 Series Reference Manual page 112

10 wireless communications test set
Hide thumbs Also See for 8960 Series:
Table of Contents

Advertisement

Step 5: INITiate and FETCh Measurements
952
Print_results("Error vector magnitude = ",Evm,"%")
953
PRINT
980
Wqu_time=PROUND(TIMEDATE-Wqu_timer,-2)
981
Print_results("WQU Test Time= ",Wqu_time,"secs")
982
PRINT
983
!
984
!
985
!***********************
986
! FRAME ERROR RATE TEST*
987
!***********************
988 !
989
!***Set up measurement parameters***
990
!
991
Ior=-70
993
Pilot=-7
994
Traffic=-15.6
995 !
997
OUTPUT Testset;"CALL:POW ";Ior
998
OUTPUT Testset;"CALL:PIL ";Pilot
999
OUTPUT Testset;"CALL:FCH ";Traffic
1000
!
1001
!***Obtain measurement results***
1002
Fer_timer=TIMEDATE
1003
OUTPUT Testset;"INIT:CFER"
1004
DISP "Measuring FER"
1005
LOOP
1006
OUTPUT Testset;"INIT:DONE?"
1007
ENTER Testset;Meas_done$
1008
EXIT IF Meas_done$="CFER"
1009
END LOOP
1010
OUTPUT Testset;"FETC:CFER?"
1012
ENTER Testset;Integrity,Fer_test,Fer_ratio,Fer_count,Frames_tested
1013
!
1014
SELECT Fer_test
1015
CASE 0
1016
Pass_fail$="PASSED"
1017
CASE 1
1018
Pass_fail$="FAILED"
1019
CASE 2
1020
Pass_fail$="MAXIMUM NUMBER OF FRAMES WERE TESTED"
1021
CASE 3
1022
Pass_fail$="UNKNOWN"
1023
END SELECT
1024
!
1025
!***Print FER Results***
1026 !
1027
DISP "FER Test complete"
1028
!
1029
PRINT "Frame Error Rate Test Results:"
1030 !
1031
PRINT "
1032
Print_res_str("FER Test Results",Pass_fail$)
1033
Print_results("FER Ratio",Fer_ratio,"%")