Agilent Technologies 8960 Series Reference Manual page 522

10 wireless communications test set
Hide thumbs Also See for 8960 Series:
Table of Contents

Advertisement

SETup:CCTPhase
SETup:CCTPhase:COUNt:STATe
Function
Sets/queries the code channel timing and phase error multi-measurement state.
Setting
Range: 1|ON|0|OFF
Query
Range: 1|0
*RST Setting
0 (off)
Programming Example
OUTPUT 714;"SETUP:CCTPHASE:COUNT:STATE ON" !Turns on code channel timing and phase error
multi-measurements.
SETup:CCTPhase:PERRor[:LIMit]
Function
Sets/queries the code channel phase error limit.
Setting
Range: 0 to 1.00 radian
Resolution: 0.01 radian
Query
Range: 0 to 1.00 radian
*RST Setting
0.15 radian
Programming Example
OUTPUT 714;"SETUP:CCTPHASE:PERROR 0.25"
SETup:CCTPhase:TERRor[:LIMit]
Function
Sets/queries the code channel timing error limit.
Setting
Range: 0 to 100.0 ns
Resolution: 0.1 ns
Query
Range: 0 to 100.0 ns
*RST Setting
10.0 ns
Programming Example
OUTPUT 714;"SETUP:CCTPHASE:TERROR 25"
522
S:\Hp8960\E1962B CDMA 2000\Pi Release\Reference Guide\Chapters\cdma2000_hpib_setup_cctphase.fm

Hide quick links:

Advertisement

Table of Contents