CALL:SCHannel:LEVel[:SELected]
Function
Sets/queries the level of the forward supplemental channel (SCH).
The optional [:SELected] keyword in this command specifies that the SCH level being set/queried
applies to the current system type. At this time there is only one system type choice,
DIGital2000. Specifying DIGital2000 will have the same effect as using the optional [:SELected]
keyword.
Setting
Range: 0 to -20 dB
Resolution: 0.01 dB
Query
Range: 0 to -20 dB
Resolution: 0.01 dB
*RST Setting
-15.6 dB
Programming Example
OUTPUT 714;"CALL:SCHANNEL:LEVEL:SELECTED -10"
CALL:SCHannel:STATe[:SELected]
Function
Sets/queries the on/off state of the forward supplemental channel (SCH).
The optional [:SELected] keyword in this command specifies that the SCH state being
set/queried applies to the current system type. At this time there is only one system type choice,
DIGital2000. Specifying DIGital2000 will have the same effect as using the optional [:SELected]
keyword.
Setting
Range: 1|ON|0|OFF
Query
Range: 1|0
*RST Setting
ON
Programming Example
OUTPUT 714;"CALL:SCHANNEL:STATE:SELECTED OFF"
!Turns off the forward supplemental channel.
S:\Hp8960\E1962B CDMA 2000\Pi Release\Reference Guide\Chapters\cdma2000_hpib_call_schannel.fm
CALL:SCHannel
371