SETup:CPOWer:TIMeout[:STIMe]
Function
The setting form of this command performs two functions: (1) sets the channel power
measurement's timeout (see
timeout STATe to 1 (on).
The query form returns the channel power measurement's timeout value.
Setting
Range: 0.1 to 999.9 seconds
Resolution: 0.1 second
Query
Range: 0.1 to 999.9
*RST Setting
10 seconds, on
Programming Example
OUTPUT 714;"SETUP:CPOWER:TIMEOUT:STIME 5 S"
!Sets timeout state to ON and sets the timeout time to 5 seconds.
SETup:CPOWer:TIMeout:STATe
Function
Sets/queries the channel power measurement's timeout (see
Setting
Range: 1|ON|0|OFF
Query
Range: 1|0
*RST Setting
0 (off)
Programming Example
OUTPUT 714;"SETUP:CPOWER:TIMEOUT:STATE ON"
SETup:CPOWer:TIMeout:TIME
Function
Sets/queries the channel power measurement's timeout (see
the timeout state is set to ON.
Setting
Range: 0.1 to 999.9 seconds
Resolution: 0.1 second
Query
Range: 0.1 to 999.9
*RST Setting
10 seconds
Programming Example
OUTPUT 714;"SETUP:CPOWER:TIMEOUT:TIME 5 S"
"Timeouts"
) value, and (2) sets the channel power measurement's
S:\Hp8960\E1962B CDMA 2000\Pi Release\Reference Guide\Chapters\cdma2000_hpib_setup_cpower.fm
"Timeouts"
) state.
"Timeouts"
) setting to be used when