CALL:CONNected:DROP:TIMer[:STATe]
Function
Sets/queries the call drop timer. The call drop timer indicates loss of reverse link. This timer also
determines when the demodulation of the reverse link has been unsuccessful for a fixed period.
The call drop timer is actually a counter that counts bad frames. The counter counts for 250
consecutive bad frames (which takes about 5 seconds). The counter is reset whenever a good
frame is received.
Setting
Range: 1|ON|0|OFF
Query
Range: 1|0
*RST Setting
ON
Programming Example
OUTPUT 714;"CALL:CONNECTED:DROP:TIMER:STATE 0"
CALL:CONNected:LIMit[:STATe]
Function
When call limit mode is on, the test set will not respond to the access probe for origination or
page responses from the mobile. For either a base station page or mobile station origination, this
command forces the mobile to repeatedly send access probes.
Setting
Range: 1|ON|0|OFF
Query
Range: 1|0
*RST Setting
ON
Programming Example
OUTPUT 714;"CALL:CONNECTED:LIMIT 0"