Summary Of Parameter Settings; Group 0 System Parameters - Delta Electronics AC Motor Drive VFD-VE Series User Manual

Vfd-ve series high performance field oriented control ac motor drive
Table of Contents

Advertisement

Chapter 4 Parameters|

4.1 Summary of Parameter Settings

: The parameter can be set during operation.

Group 0 System Parameters

Pr.
Explanation
Identity Code of the AC
00-00
motor drive
Rated Current Display of
00-01
the AC motor drive
Parameter Reset
00-02
00-03 Start-up Display Selection
Content of Multi Function
00-04
Display
00-05 User-Defined Coefficient K
00-06
Software Version
00-07 Password Input
00-08 Password Set
00-09 Energy Saving Gain
Control Method
00-10
V/f Curve Selection
00-11
Constant/Variable Torque
00-12
Selection
Optimal
Acceleration/Deceleration
00-13
Setting
4-2
Settings
Read-only
Read-only
0: No function
1: Read only
2: Enable group 11 parameters setting
8: Keypad lock
9: All parameters are reset to factory settings (50Hz,
220V/380V)
10: All parameters are reset to factory settings (60Hz,
220V/440V)
0: Display the frequency command value (LED F)
1: Display the actual output frequency (LED H)
2: Multifunction display, see Pr.00-04 (LED U)
3: Display the output current (A)
0: Display output current (A)
1: Display counter value (C)
2: Display output frequency (H)
3: Display DC-BUS voltage ( u )
4: Display output voltage (E)
5: Output power factor angle (n)
6: Display output power (kW)
7: Display actual motor speed (HU)
8: Display estimate output torque (kg-m)
9: Display PG position (G) (refer to Pr.10-00 and Pr.10-
01)
10: Display PID feedback
11: Display AVI (%)
12: Display ACI (%)
13: Display AUI (%)
14: Display the temperature of heat sink (°C)
15: Display the temperature of IGBT (°C)
16: The status of digital input (ON/OFF)
17: The status of digital output (ON/OFF)
18: Multi-step speed
19: The corresponding CPU pin status of digital input
20: The corresponding CPU pin status of digital output
21: Number of actual motor revolution (PG1 of PG card)
22: Pulse input frequency (PG2 of PG card)
23: Pulse input position (PG2 of PG card)
Digit 4: decimal point number (0 to 3)
Digit 0-3: 40 to 9999
Read-only
1 to 9998 and 10000 to 65535
0 to 2: times of wrong password
1 to 9998 and 10000 to 65535
0: No password set or successful input in Pr.00-07
1: Password has been set
10~1000 %
0: V/f Control
1: V/f Control + Encoder (VFPG)
2: Sensorless vector control (SVC)
3: FOC vector control + Encoder (FOCPG)
4: Torque control + Encoder (TQRPG)
0: V/f curve determined by group 01
1: 1.5 power curve
2: Square curve
0: Constant Torque (100%)
1: Variable Torque (125%)
0: Linear accel./decel. I
1: Auto accel., linear decel.
2: Linear accel., auto decel.
3: Auto accel./decel.
Factory
VF VFPG SVC FOCPG TQRPG
Setting
0
0
0
0
0
0
#.#
0
0
100%
0
0
0
0
Revision August 2008, 03VE, SW V2.04

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents