Terminals
5V
Output power 500mA Max
GND

Analog signal common terminal

This GND terminal is only used for 5V terminal on EMV-APP01. Please do NOT
confuse with DCM terminal.
SO1-MCM
Multi-function analog voltage output terminal 0~10.0V (output current: 2mA Max.)
SO2-MCM
Analog output is set by Pr.03-21 and Pr.03-24.
MI7~MIB

Multi-function input terminals

Please refer to Pr.02-23 to Pr.02-27 for MI7-GND~MIB-GND function selection. Take
terminals MI7-GND for example, ON: the activation current is 6.5mA and OFF:
leakage current tolerance is 10μA.

MO3~MOA Multi-function output terminals (photocoupler)

The AC motor drive outputs each monitor signal, such as during operation, frequency
attained and overload, by transistor with open collector. Please refer to Pr.03-35 to
Pr.03-42 for details.
MO3~M OA-MC M
internal c ircui t
MCM
Multi-function output common terminal. Max: 48Vdc/50mA
This MCM terminal is only used with MO3~MOA on EMV-APP01. Please do NOT
confuse with terminal MCM.
Revision August 2008, 03VE, SW V2.04
NOTE
Ma x: 48 Vd c/50 mA
MO 3
~
MOA
MC M
NOTE