Delta Electronics AC Motor Drive VFD-VE Series User Manual page 76

Vfd-ve series high performance field oriented control ac motor drive
Table of Contents

Advertisement

Pr.
Explanation
Multi-function Output 5 (MO3)
02-35
Multi-function Output 6 (MO4)
02-36
Multi-function Output 7 (MO5)
02-37
Multi-function Output 8 (MO6)
02-38
Multi-function Output 9 (MO7)
02-39
Multi-function Output 10 (MO8)
02-40
Multi-function Output 11 (MO9)
02-41
Multi-function Output 12 (MOA)
02-42
Group 3 Analog Input/Output Parameters
In version 2.02, the parameters are from Pr.03-00 to Pr.03-20. The settings for Pr.03-00 to
Pr.03-02 are from 0 to 10
Pr.
Explanation
Analog Input 1 (AVI)
03-00
Analog Input 2 (ACI)
03-01
Analog Input 3 (AUI)
03-02
Analog Output Value in REV Direction
03-20
Group 6 Protection Parameters
In version 2.02, the parameters are from Pr.06-00 to Pr.06-31. The settings of Pr.06-01 are
shown as follows. The settings for Pr.06-17 to Pr.06-22 are from 0 to 62.
Pr.
Explanation
Over-voltage Stall Prevention
06-01
06-17
Present Fault Record
06-18
Second Most Recent Fault Record
06-19
Third Most Recent Fault Record
06-20
Fourth Most Recent Fault Record
06-21
Fifth Most Recent Fault Record
06-22
Sixth Most Recent Fault Record
Revision August 2008, 03VE, SW V2.04
Settings
33: Zero speed (actual output
frequency)
34: Zero speed with Stop (actual output
frequency)
35: Error output selection 1 (Pr.06-23)
36: Error output selection 2 (Pr.06-24)
37: Error output selection 3 (Pr.06-25)
38: Error output selection 4 (Pr.06-26)
39: Position attained (Pr.10-19)
40: Speed attained (including zero
speed)
41: Multi-position attained
42: Crane function
Settings
2: torque command (torque limit under
speed mode)
3: Torque compensation command
4: PID target value (refer to group 8)
5: PID feedback signal (refer to group
8)
6: P.T.C. thermistor input value
7: Positive torque limit
8: Negative torque limit
9: Regenerative torque limit
10: Positive/negative torque limit
0: Absolute value in REV direction
1: Output 0V in REV direction
2: Enable output voltage in REV
direction
Settings
0.0: Disable
350.0~450.0Vdc
700.0~900.0Vdc
0: No fault
1: Over-current during acceleration
(ocA)
2: Over-current during deceleration
(ocd)
3: Over-current during constant speed
(ocn)
Chapter 4 Parameters|
Factory
VF VFPG SVC FOCPG TQRPG
Setting
Factory
VF VFPG SVC FOCPG TQRPG
Setting
0
0
Factory
VF VFPG SVC FOCPG TQRPG
Setting
380.0
760.0
0
0
0
0
0
0
4-27