Group 10 Speed Feedback Control Parameters - Delta Electronics AC Motor Drive VFD-VE Series User Manual

Vfd-ve series high performance field oriented control ac motor drive
Table of Contents

Advertisement

Group 10 Speed Feedback Control Parameters

Pr.
Explanation
10-00
Encoder Pulse
10-01
Encoder Input Type
Setting
PG Feedback Fault
10-02
Treatment
Detection Time for PG
10-03
Feedback Fault
ASR (Auto Speed
10-04
Regulation) Control
( P) 1
ASR (Auto Speed
10-05
Regulation) Control (I)
1
ASR (Auto Speed
10-06
Regulation) Control
( P) 2
ASR (Auto Speed
10-07
Regulation) Control (I)
2
ASR 1/ASR2 Switch
10-08
Frequency
ASR Primary Low
10-09
Pass Filter Gain
PG Stall Level
10-10
PG Stall Detection
10-11
Time
PG Slip Range
10-12
PG Slip Detection
10-13
Time
PG Stall and Slip Error
10-14
Treatment
Pulse Input Type
10-15
Setting
Output Setting for
10-16
Frequency Division
(denominator)
PG Electrical Gear A
10-17
(Channel 1 of PG
card)
PG Electrical Gear B
10-18
(Channel 2 of PG
card)
PG Position Control
10-19
Point (Home)
Range for PG Position
10-20
Attained (Home range)
Revision August 2008, 03VE, SW V2.04
Settings
1~20000
0: Disable
1: Phase A leads in a forward run command and phase
B leads in a reverse run command
2: Phase B leads in a forward run command and phase
A leads in a reverse run command
3: Phase A is a pulse input and phase B is a direction
input. (low input=reverse direction, high input=forward
direction)
4: Phase A is a pulse input and phase B is a direction
input. (low input=forward direction, high input=reverse
direction)
5: Single-phase input
0: Warn and keep operation
1: Warn and ramp to stop
2: Warn and coast to stop
0.00~10.0 sec
0~40
0.000~10.000 sec
0~40
0.000~10.000 sec
5.00~600.00Hz
0.000~0.350 sec
0~120% (0: disable)
0.0~2.0 sec
0~50% (0: disable)
0.0~10.0 sec
0: Warn and keep operation
1: Warn and ramp to stop
2: Warn and coast to stop
0: Disable
1: Phase A leads in a forward run command and phase
B leads in a reverse run command
2: Phase B leads in a forward run command and phase
A leads in a reverse run command
3: Phase A is a pulse input and phase B is a direction
input. (low input=reverse direction, high input=forward
direction)
4: Phase A is a pulse input and phase B is a direction
input. (low input=forward direction, high input=reverse
direction)
1~255
1~5000
1~5000
0~20000
0~20000
Chapter 4 Parameters|
Factory
VF
VFPG SVC
Setting
600
0
2
1.0
10
0.100
10
0.100
7.00
0.008
115
0.1
50
0.5
2
0
1
100
100
0
10
FOCPG TQRPG
4-23

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents