Chapter 4 Parameters|
When output frequency reaches Y-connection/Δ −connection switch frequency, drive will delay
by Pr.05-30 before multi-function output terminals are active.
Y-
connection switch: can be used for wide range motor
 
Y connection for low speed: higher torque can be used for rigid tapping
connection for high speed: higher torque can be used for high-speed drilling
connection is finished
Pr.02-01~06=30
Y-connection is finished
Pr.02- 01~06=29
Pr.05-11
Y-
switch
frequency
Motor speed/
frequency
Y-connection output
Y-conenction
confirmation input
△-connection output
Pr.02-11~14=32
△-connection
confirmation input
Pr.02-11~14=30
4-90
U
MI1
V
W
connection control
MI2
RA
Y connection control
MRA
Y-connection
confirmation input
If switch point is 60Hz,
the accel. switch point is 62Hz
In this area, motor is in free
run status. AC motor drive
stops outputting.
Pr. 05-30 Delay Time for Y-connection
/D -connection(Min. is 0.2 seconds)
ON
Pr.02-11~14=31
ON
Pr.02-11~14=29
Pr.02- 11~14= 32
Pr.02- 11~ 14= 31
ON
ON
mechanical bounce time
:
Revision August 2008, 03VE, SW V2.04
U
V
W
IM
X
Y
Z
Decel. switch point is 58Hz
Bandwidth is 2Hz
Motor speed will
decrease
by load inertia.
ON
ON