Delta Electronics AC Motor Drive VFD-VE Series User Manual page 85

Vfd-ve series high performance field oriented control ac motor drive
Table of Contents

Advertisement

Chapter 4 Parameters|
Pr.
Explanation
Reel Diameter
Current Reel Diameter
08-54
Smart Start
08-55
Switch Level for Smart
08-56
Start and PID function
Frequency for Smart
08-57
Start
Accel. Time for Smart
08-58
Start
Broken Belt Detection
08-59
Min. Line Speed of
08-60
Broken Belt Detection
Allowance Error of Line
08-61
Speed of Broken Belt
Detection
Detection Time of
08-62
Broken Belt
Allowance Error Level
08-63
of Tension/Line Speed
PID Feedback
Allowance Error
08-64
Detection Time of
Tension PID Feedback
Error Treatment of
08-65
Tension PID Feedback
Upper Limit of Tension
08-66
PID Feedback
Lower Limit of Tension
08-67
PID Feedback
Reserved
08-68
DFM Selection
08-69
Low-pass Filter Time of
08-70
Line Speed
08-71
|
Reserved
08-75
Source of Tension
08-76
Setting
Max. Tension
08-77
Tension Setting
08-78
Source of Zero-speed
08-79
Tension Setting
Setting of Zero-speed
08-80
Tension
Source of Tension
08-81
Taper
Tension Taper
08-82
Friction Compensation
08-83
Compensation
08-84
Coefficient of Material
Inertial
Torque Feed Forward
08-85
Gain
Low Pass Filter Time of
08-86
Torque Feed Forward
08-87
Reserved
|
08-99
4-36
Settings
1: Enable
1.0~6000.0mm
0: Disable
1: Enable
2: In unwind mode, rewind in reverse direction
0.0~100.0% (according to Pr.08-26)
0.00~600.00Hz
0.01~600.00 seconds
0: Disable
1: Enable
0.0~3000.0m/min
1.0~6000.0mm
0.00~100.00 sec
0~100%
0.0~10.0 sec
0: Warn and keep operation
1: Warn and coast to stop
2: Warn and ramp to stop
0.0~100.0%
0.0~100.0%
0: Output frequency
1: Frequency command
0.00~100.00 sec
0: Communication RS-485 (Pr.08-78)
1: Analog input (Pr. 03-00~03-02 is set to 15
tension setting) (Pr.08-78)
0~30000 N
0~30000 N
0: Disable
1: Communication RS-485 (Pr.08-80)
2: Analog input (Pr. 03-00~03-02 is set to 16 zero-
speed tension) (Pr.08-80)
0~30000 N
0: Communication RS-485 (Pr.08-82)
1: Analog input (Pr. 03-00~03-02 is set to 17
tension taper)(Pr.08-82)
0~100%
0.0~100.0%
0~30000
0.0~100.0%
0.00~100.00
Factory
VF VFPG SVC FOCPG TQRPG
Setting
1.0
1
15.0
2.00
3.00
0
0.0
100.0
1.00
100
0.5
0
100.0
0.0
0
0.00
0
0
0
0
0
0
0
0.0
0
50.0
5.00
Revision August 2008, 03VE, SW V2.04