Summary Of Parameter Settings; User Parameters; Chapter 4 Parameters - Delta Electronics AC Motor Drive VFD-G User Manual

Vfd-g series specific ac motor drives for plastic molding and air compressors machinery
Table of Contents

Advertisement

Chapter 4 Parameters|

4.1 Summary of Parameter Settings

: The parameter can be set during operation.
Group 0 User Parameters
Parameter
Functions
00-00
Software Version
00-01
AC Drive Status
Indication 1
4-2
Settings
Read only
00: No Fault occurred
01: oc (over current)
02: ov(over voltage)
03: oH(over temperature)
04: oL(overload)
05: oL1(electronic thermal relay)
06: EF(external Fault)
07: occ(AC drive IGBT fault)
08: CF3(CPU failure)
09: HPF(Hardware Protection Failure)
10: ocA(current exceed during Acceleration)
11: ocd(current exceed during Deceleration)
12: ocn(current exceed during Steady State)
13: GFF(Ground Fault)
14: Lv(Low voltage)
15: CF1(abnormal input data)
16: CF2(abnormal output data)
17: bb(Base Block)
18: oL2(over load2)
19: Reserved
20: codE(software or password protection)
21: EF1(external Emergency Stop)
22: PHL(phase loss)
23: Lc (Low Current)
24: FbL(Feedback Loss)
25: Reserved
26: FANP (Fan Power Fault)
27: FF1 (Fan 1 Fault)
28: FF2 (Fan 2 Fault)
29: FF3 (Fan 3 Fault)
30: FF123 (Fan 1, 2, 3 Fault)
31: FF12 (Fan 1, 2 Fault)
32: FF13 (Fan 1, 3 Fault)
33: FF23 (Fan 2, 3 Fault)
34: Fv (Gate Drive Low Voltage Protect)
35~40: Reserved
41: HPF1 (GFF hardware error)
42: HPF2 (CC,OC hardware error)
Factory
Setting
Read
Revision July 2008, EG03, SW V1.06
Customer

Advertisement

Table of Contents
loading

Table of Contents