Digital Output Gain; Desired Frequency Attained 1; The Width Of The Desired Frequency Attained 1; Desired Frequency Attained 2 - Delta Electronics AC Motor Drive VFD-VE Series User Manual

Vfd-ve series high performance field oriented control ac motor drive
Table of Contents

Advertisement

Chapter 4 Parameters|
Display value
[00-04=01]
[02-06=23]
TRG
Counter Trigger
(output signal)
Preliminary Counter Value
(Pr.02-11 ~ Pr.02-14)
Terminal Counter Value
02-18

Digital Output Gain

Control
VF
VFPG
mode
Settings
It is used to set the signal for the digital output terminals (DFM-DCM) and digital frequency
output (pulse X work period=50%). Output pulse per second = output frequency X Pr.02-18.
02-19

Desired Frequency Attained 1

Control
VF
VFPG
mode
02-20

The Width of the Desired Frequency Attained 1

Control
VF
VFPG
mode
02-21

Desired Frequency Attained 2

Control
VF
VFPG
mode
02-22
The Width of the Desired Frequency Attained 2
Control
VF
VFPG
mode
Settings
Once output frequency reaches desired frequency and the corresponding multi-function output
terminal is set to 3 or 4 (Pr.02-11~Pr.02-14), this multi-function output terminal will be ON.
4-76
02-13=18
02-14=17
SVC
FOCPG TQRPG
1 ~ 40
SVC
FOCPG
SVC
FOCPG
SVC
FOCPG
SVC
FOCPG
0.00 ~ 600.00Hz
02-17=3
02-16=5
Revision August 2008, 03VE, SW V2.04
The width of trigger signal
Factory setting: 1
Unit: 0.01
Factory setting: 60.00/50.00
Unit: 0.01
Factory setting: 2.00
Unit: 0.01
Factory setting: 60.00/50.00
Unit: 0.01
Factory setting: 2.00
Unit:1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents