Full-Load Current Of Motor 2; Rated Power Of Motor 2; Rated Speed Of Motor 2 (Rpm) - Delta Electronics AC Motor Drive VFD-VE Series User Manual

Vfd-ve series high performance field oriented control ac motor drive
Table of Contents

Advertisement

Y-connection output
Pr.02-11~14=31
Y-connection
confirmation input
Pr.02-01~06=29
△-connection output
Pr.02-11~14=32
△-connection
confirmation input
Pr.02-01~06=30
Y-
switch error
frequency
05-13

Full-load Current of Motor 2

Control
VF
VFPG
mode
Settings
This value should be set according to the rated frequency of the motor as indicated on the
motor nameplate. The factory setting is 90% X rated current.
Example: The rated current for 7.5HP (5.5kW) is 25 and factory setting is 22.5A. The range for
setting will be 10~30A.(25*40%=10 and 25*120%=30)
05-14

Rated Power of Motor 2

Control
SVC
FOCPG TQRPG
mode
Settings
It is used to set rated power of the motor 2. The factory setting is the power of the drive.
05-15

Rated Speed of Motor 2 (rpm)

Control
VFPG
SVC
mode
Settings
It is used to set the rated speed of the motor and need to set according to the value indicated
on the motor nameplate.
Revision August 2008, 03VE, SW V2.04
output
frequency
ON
ON
SVC
FOCPG TQRPG
40 to 100%
0 to 655.35
FOCPG TQRPG
0 to 65535
free run status
ON
2 seconds
delay time
Pr.05-30
Chapter 4 Parameters|
ON
Factory setting: #.##
Factory setting: #.##
Factory setting: 1710
Unit: 1%
Unit: 0.01
Unit: 1
4-91