Download Print this page

Konica Minolta bizhub C4000i Service Manual page 264

Hide thumbs Also See for bizhub C4000i:

Advertisement

bizhub C4000i/C3300i
2.  USB memory
2.1  Preparation
System preparation
• PC with USB ports
• USB memory
• USB flash memory compatible with the USB (1.1/2.0/3.0) interface. The speed is limited to USB2.0 specifications even if using a
device that supports USB3.0.
• The USB memory is formatted in FAT32 format.
• No security functions such as encryption and password lock have been added (or the USB memory allows its security functions to be
turned OFF).
• A USB memory that is recognized by the computer as two or more drives cannot be used.
NOTE
▪ Possible to be non-operational products.
USB memory used to update firmware
1. Uncompress the firmware file.
2. Connect the USB memory to the computer.
3. Copy the extracted update data folder into the root directory of the USB memory.
Product name
bizhub C4000i/C3300i
NOTE
▪ More than one firmware data with a single model can be stored in the USB memory.
▪ In this case, copy the firmware data to the USB memory according to the following procedures.
1. Make the folder named "FWSelect" (case-sensitive) to the root directory of the USB memory.
2. Make a folder with any folder name (one byte alphameric characters, maximum 40 characters) under "FWSelect" folder, and
store the firmware data to the folder.
Directory configuration of USB memory
[1]
[2]
FW****
[3]
FWSelect
[1]
USB memory
[3]
Storage folder for a plurality of data (Folder name:
FWSelect (Fixed)) *2
[5]
Storage folder for firmware data C (Folder name:
Arbitrary) *2
• *1: Required to start the firmware update screen.
• *2: Required only when a plurality of data is stored.
2.2  Rewriting of Firmware
Starting the update screen
NOTE
▪ When [Administrator] -> [Security] -> [USB Connection Permission setting] -> [External Memory (Service)] -> [FW Update] is set
to "Restrict", firmware update cannot be executed by using a USB memory.
▪ When the main power switch is turned on, a message "It is limited by the administrator." will appear.
▪ When [Administrator] -> [Security] -> [FW Update (USB) Perm. Sett.] is set to "Password Priority", it requires to input a password
after confirming with the administrator.
▪ USB memory must be connected with the main power switch off.
<Procedure>
1. Turn OFF the main power switch.
2. Connect the USB memory containing the firmware into the USB port on the right side of the control panel.
Firmware Data Ver.A
Firmware Data Ver.B
[4]
Folder1
Firmware Data Ver.C
[5]
Folder2
Firmware Data Ver.D
[6]
Folder3
Rewriting data folder name
FW0023
[2]
Rewriting data folder (Required) *1
[4]
Storage folder for firmware data B (Folder name:
Arbitrary) *2
[6]
Storage folder for firmware data D (Folder name:
Arbitrary) *2
K-2
K FIRMWARE > 2. USB memory

Advertisement

loading

This manual is also suitable for:

Bizhub c3300i