Bit Assignment
00000000
00000010
Reference
• [Service Mode] -> [System 2] -> [Unit Change]
10.4.14  SW No.152
• The E-mail body print settings of E-Mail RX Print
Bit Assignment
00000000
00000001
• This function supports the following languages.
• Japanese, English, French, Italian, Germany, Spanish
10.4.15  SW No.155
• Validation/invalidation of the debug setting of the log.
Bit Assignment
00000000
00000001
Reference
• [Service Mode] -> [Debug Settings] -> [Basic mode]
10.4.16  SW No.157
• Change the upper limit of the time for switching to power save mode.
Bit Assignment
00000000
00000010
Reference
• [Administrator] -> [Maintenance] -> [Timer Setting] -> [Power Settings] -> [Low Setting]
10.4.17  SW No.163
• Setting for the auto execution of Self-diag.(Full)
Bit Assignment
00000000
00000010
10.4.18  SW No.188
• Operation setting for print status LED
Bit Assignment
00000001
00000010
10.4.19  SW No.203
• Setting to automatically change log-in authorization to a second user when the second user attempts card authentication after a first user
has been authenticated through card authentication.
Bit Assignment
00000000
00000100
10.4.20  SW No.206
• Setting whether to enable Coverage Counter
Bit Assignment
00000000
00000001
Reference
• [Service Mode] -> [Billing Setting] -> [Coverage Rate Clear], [Print Counter Clear], [Coverage Counter Detail]
10.4.21  SW No.227
• Setting for the display of consumable level and warning. (Control panel, Web Connection, Fiery)
HEX Assignment
00
Hide
02
Display
HEX Assignment
00
Disables the E-mail body print settings.
01
Allows the E-mail body print settings.
HEX Assignment
00
Debug setting is disabled.
01
Debug setting is enabled.
HEX Assignment
00
Do not change the upper limit.
02
Change the upper limit to 240 minutes.
HEX Assignment
00
Disable
02
Enable
The Self-diag. (Full) will be executed automatically only
when the rank B/C trouble codes are detected.
HEX Assignment
00
Blinking
02
Unlit
HEX Assignment
00
Log-in not authorized.
04
Log-in authorized.
HEX Assignment
00
Disable
01
Enable
Details
Details
Details
Details
Details
Details
Details
Details
I-33
I SERVICE MODE > 10. System 2
Default value (Bit/HEX)
00000010 / 02
Default value (Bit/HEX)
00000000 / 00
Default value (Bit/HEX)
00000000 / 00
Default value (Bit/HEX)
00000000 / 00
Default value (Bit/HEX)
00000000 / 00
Default value (Bit/HEX)
00000001 / 01
Default value (Bit/HEX)
00000000 / 00
Default value (Bit/HEX)
00000000 / 00