10.11  Install Data
• To install voice data into MFP.
• Selection of [OEM] makes customization of driver name, etc. possible by writing the OEM extended character string in the firmware
package and downloading it.
NOTE
▪ In the following conditions, import of data is prohibited.
▪ [Administrator] -> [Security] -> [USB Connection Permission setting] is set to [Restrict].
▪ [Administrator] -> [Security] -> [USB Connection Permission setting] -> [Detail Setting] -> [External Memory(Service)] is set
to [Restrict].
▪ [Administrator] -> [Security] -> [Enhanced Security Mode] is set to "ON."
• To install the voice guidance, check if [Administrator] -> [System Settings] -> [Voice Guidance Settings] -> [Voice Guidance] is
set to "Yes".
<Procedure>
1. Save installation data (*.tar) into the root directory of a USB memory device.
2. Connect the USB memory device to the machine USB port.
3. Touch [Install Data].
4. Select the type of the data to be installed.
• You can select multiple types of data at a time and install them.
5. Touch [Set].
6. Press the Start key to install the data.
7. Check result "OK" is displayed and touch [END].
NOTE
▪ If data is already installed, it is necessary to delete old data before installing new one.
▪ * To delete registered data, select the data to be deleted, and touch [Delete] -> [Fix]. Check result "OK" is displayed.
10.12  Local Interface Kit Setting
• To set whether to enable or disable the Bluetooth function.
• Use this setting upon set-up of the optional local interface kit.
Set
Unset
10.13  Display Eco Index
• To set whether or not to display [Power Consumption] and [CO2 Emission] in [Utility] -> [Counter] -> [Eco Info].
NOTE
▪ The amount of power consumption displayed on MFP is an estimated value calculated from the average amount of power
consumption and the operating hours of MFP, so that is not an exact power consumption value. Therefore, explain this to
users before selecting the option of displaying these items.
• To set an emission coefficient used to calculate the amount of CO2 emission.
NOTE
▪ As the CO2 emission coefficient is different depending on the electric power provider with whom the user contracts and the
user's MFP use environment, the coefficient needs to be set individually.
Setting item
Power Savings Display Level
Output Coefficient Settings
<Procedure>
1. Explain to users that [Power Consumption] and [CO2 Emission] displayed on MFP are estimated values, and obtain their consent.
2. Select [ON] in [Power Savings Display Level].
3. Depending on the user's MFP use environment, configure [Output Coefficient Settings] using the 10-key pad.
4. Touch [END].
10.14  Internal Error. Auto Cancel
• To set whether or not to automatically reset trouble when a trouble code classified as rank B or C occurs.
Setting item
Rank B
Rank C
<Operation when set to "Yes">
1. When specified trouble occurs, the trouble warning screen displays for about 10 seconds the message that the trouble is automatically
reset. Then automatic trouble reset is performed.
2. If the trouble reset is successful, MFP can be used.
• If the trouble reset fails, retry is performed. (The number of retries is up to 2 times.)
10.15  Acquiring Settings
• To count frequency of use by each function and collect machine configuration information.
Setting value
ON
OFF
0.0001 - 0.9999
Yes
No
Yes
No
Setting
Setting value
I-38
I SERVICE MODE > 10. System 2
Default setting
Default setting
0.4166
Default setting