d. INSPECTION
NOTICE
• Use a known-good battery.
• Do not connect the battery for more than 30 seconds. Wait for
one minute or more before connecting the battery again.
• PGM-FI MAIN RELAY
1) Connect the battery positive (+) terminal to the Black/Yellow
terminal of the PGM-FI main relay 6P connector and the
battery negative (–) terminal to the Black terminal. There
must be the continuity between the following terminals of
the 4P connector.
• Between White/Yellow and White/Green terminals
• Between White/Yellow and White/Red terminals
• Between White/Yellow and White/Black terminals
2) Connect the battery positive (+) terminal to the PGM-FI
main relay terminal and the battery negative (–) terminal to
the Light green/Red terminal. There must be the continuity
between the White/Black and the Blue/Red terminals of the
2P connector.
3) Connect the battery positive (+) terminal to the Black/White
terminal of the PGM-FI main relay 6P connector and the
battery negative (–) terminal to the Black/Blue terminal.
There must be continuity between the terminal and the
White/Yellow terminal of the 4P connector.
4) Connect the battery positive (+) terminal to the White/
Green terminal of the PGM-FI main relay 4P connector and
the battery negative (–) terminal to the 6P connector Light
green/Red terminal. There must be continuity between the
White/Black and the Blue/Red terminals of the 2P
connector.
5) If there is no continuity, replace the PGM-FI main relay.
18-24
[1]
CONNECTORS VIEWED
FROM THE FRONT SIDE
W/G
W/R
W/Bl
W/Y
Lg/R
Bl
[1]
[2]
4P CONNECTOR
PGM-FI MAIN RELAY
W/G
W/R
W/Bl
W/Y
[3]
2P CONNECTOR
W/Bl
Bu/R
[4]
6P CONNECTOR
Bl/Bu
Bl/W
Lg/R
Bl/Y
Bl
[5] TERMINAL
W/Bl
Bu/R
Bl/Y
Bl/Bu
Bl/W