Reissued:21-Apr-14
Model:
Aries-P1.5/C1.5
e) Slide in a piece of paper in the doctor gap to remove developer mixture stuck in
the gap.
f)
Use a vacuum cleaner to remove the remaining particles.
IMPORTANT: Work carefully to avoid damage to the development rollers.
g) Follow the above step in reverse order to put back the development unit.
4. Do "No.208 Execute Toner Refreshing" in the Adjustment Settings for Skilled
Operators Menu so that clumps of toner/developer are removed and do not clog
the doctor gap.
5. Run the customer job.
Are the results accepted by the customer?
Yes: Finish
No: Repeat steps 2 and 3 because the developer unit still contains clumps of
toner/developer.
6. Replace the developer mixture of the affected color by referring to the
procedures described in RTB RM077072a, if the doctor gap is still clogged even
after repeating steps 2~4 twice.
echnical
T
B
ulletin
Date:
10-Mar-14
PAGE: 31/75
No.:
RM077107b