Cleaning the fusing exit guide assembly
Disassemble as described below to check for toner adhesion at the tip of the paper exit
guide assembly. If toner adhesion is confirmed, clean with alcohol.
Check for toner adhesion on these tips.
(1) Pull out the paper exit unit.
(2) Remove the lock lever [A]. (screw x1)
(3) Remove the inner cover [B]. (screw x3)
(4) Open the upper paper guide.