Reissued: 09-Nov-12
Model:
Aries-C1.5/P1.5, AG-C1/P1, AGL-C1/P1,
B-C3/C3.5/C4, DDP
Version
2. The machine stalls at a "printing in process" status in a jam where the paper is
not exit to the shift tray.
This symptom occurs only when installing the Katana-C2 and the EFI controller.
<NOTE>
Please apply firmware V1.820 or later for a configuration consisted of the Katana-
C2 and the EFI controller.
1.800:58
Symptom Corrected:
-
Jam115 when changing from Standard size to Non-standard size.
Other changes:
-
Moving distance of initialization has been changed to "2mm after sensor turn-
off".
1.600
<NOTE> Please apply Version (V1.600) onward when applying Plockmatic/GBC
on the Aegis.
Symptom Corrected:
1.
During Plockmatic connection, JAM115 occurs when operating manual
stapling.
2.
During Plockmatic connection, indication of "out of staples" does not
disappear even when staples are added after commanding a saddle-stitch
job, in which the VICTORIA-E is powered in a "out of staples" status.
3.
During Plockmatic connection, when commanding saddle-stitch of more than
2 sheets consisted of a single print using
a
4.
During GBC connection, sheets that are not assigned to be punched are
punched.
Changes made:
When operating saddle-stitch of more than 16 sheets at Plockmatic connection,
a
b
echnical
T
Modified Points or Symptom Corrected
12x18 sheet, job completion is not correctly informed in order to start the
2nd stapling function, and results in a "still copying" status.
the width of the exit guide plate opening will be set to 5mm.
the shutting timing of the exit guide plate will be when 20mm of the
leading edge goes through.