Model:
Aries-P1.5/C1.5
Subject:
PCDU Slide-rail Rework
From:
1st Tech Service Sect., PP Tech Service Dept.
Classification:
Symptom
Slide-rail could drop from the Stay when setting the C, M, and Y development units.
Cause
Mold used for creating the Stay was damaged and fixed but the dimensions of the fixed mold were incorrect.
OK
Stay with
the correct
dimensions
Slide-rail -
Projection
NG
Stay with
incorrect
dimensions
Slide-rail -
Projection
The mold used for Black is separate from the other colors, and therefore, the problem occurs only with the
Stays (positioned to the right hand side viewed from the front) for Cyan, Magenta, and Yellow.
T
echnical
Troubleshooting
Mechanical
Paper path
Product Safety
Slide-rail
7.9mm
8.18mm
Stay - Hole
7.9mm
7.58~7.68mm
Stay - Hole
B
ulletin
Date:
04-Nov-11
Prepared by:
Part information
Electrical
Transmit/receive
Other (
)
The Slide–rail is not
latched with the Stay.
The projection on the
Slide–rail fits properly in the
hole in the Stay.
The projection on the Slide-
rail is not latched to the
hole in the Stay.
PAGE: 1/7
No.:
RM077049
J. Kobayashi
Action required
Service manual revision
Retrofit information
Tier 2
Stay
Slide-rail
This figure shows the 2
components latching
properly.
The tip of the stay is
hanging on the
projection.