Supplying of the Paper Exit Unit; Ass'Y
Delivery will take approximately 2 months after order placements. (Although this will
depend on the stock).
Notes
This unit contains parts mentioned in part catalog, "Paper Exit Unit" from section 1 to
12
This unit is too heavy for one person to lift or move safely. Two people are required to
life or move the unit.
Procedure for removing the Paper Exit unit
1. Pull out the paper exit unit ass'y with the fusing unit on it.
2. Remove the fusing unit. (Refer to the service manual.)
3. Remove 2 screws on the rails, (one on the right [B], one on the left [A])
4. Remove the paper exit unit ass'y from the rails
Follow the above procedure in reverse order to re-assemble the paper exit unit.
T
B
echnical
ulletin
Date:
23-Mar-11
PAGE: 2/2
No.:
RM077022