Model:
Aries-P1.5/C1.5
4. Clean the surface of the duct with alcohol where the "Guide: Lower Duct" is to be
attached.
5. Attach the "Guide: Lower Duct" along the surface of the duct. Make sure the edge of
the "Guide: Lower Duct" is in contact with the edge of the purge guide plate; area
indicated with the blue rectangle in Fig2.
See "Fig 3" for more detailed description on where and how to attach the guide.
Purge guide plate
Make sure the edge of the "Guide: Lower
Duct" is in contact with the edge of the
"purge guide plate".
T
B
echnical
GM0774927 Guide: Lower: Duct
Attach the "Guide: Lower Duct" along the
surface of the duct
Fig 2
ulletin
Date:
21-Oct-11
PAGE: 3/4
No.:
RM077046
Duct