Model:
Aries P1.5/C1.5, AegisP1/C1
PREVENTIVE MEASURE
Take note of the following 2 points when cleaning the dust shield glass to prevent the
guide seal from peeling off.
・ When inserting the dust shield glass into the bracket, insert it straight, not at an angle.
・ Insert the dust shield glass into the bracket gently and make sure the tip of the glass is
not catching the guide seal. If you feel the glass is caught, pull it out and slide it in
again. Repeat the procedure until you confirm proper insertion.
What to do when the guide seal has been peeled off from the bracket
Temporary solution: Cut the peeled off portion of the guide seal, then insert the shield
Permanent solution: Procure new brackets. (Brackets have been newly registered as
For Yellow and Cyan
New p/n
G1782091
For Magenta and Black
New p/n
G1782092
echnical
T
glass.
service parts.)
Description
PROTECTION:SHIELD GLASS:LEFT:ASS'Y
Description
PROTECTION:SHIELD GLASS:RIGHT:ASS'Y
ulletin
B
Date:
07-Feb-14
PAGE: 2/2
No.:
RM077105