Reissued:30-Aug-13
Model:
Aries-P1.5/C1.5
RTB Reissue
The items in bold italics were added.
Subject:
Part Changes –For vertical lines
From:
1st PP Service Planning Sec., PP Service Planning
Classification:
Change: New BRUSH ROLLER:APPLY:ASS'Y
Reason: To prevent the image quality issue known as "Vertical lines" caused by excess
lubricant applied to the OPC drum
Action:
If you encounter the above image quality issue, replace the brush roller with the
new brush roller described below.
Old Part
New Part
Number
Number
GD042011
GD042012 BRUSH ROLLER:APPLY:ASS'Y
NOTES:
When replacing with the new brush roller (GD042012), make sure to remove the
"paper clips", if installed, from the previous brush roller.
The new brush roller should be replaced only for units with the drum cleaning
unit registered with the p/n M0773600. This is because the modified drum
cleaning unit (M0773601) has the new brush roller. (See the following page.)
The new brush roller applies the optimum amount of lubricant, preventing
vertical lines as a result of excess lubricant on the drum.